Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 275
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38522878

RESUMO

Ventricular septation of the double-inlet ventricle is a largely abandoned operation due to poor historical outcomes. However, there has been renewed interest in septation as an alternative to Fontan palliation given its long-term sequelae. As one of the few centers to revisit septation in the early 1990s, our institution has long-term data on a series of patients with a double-inlet ventricle who underwent biventricular repair. This manuscript is a summary of our approach to staged septation of the double-inlet ventricle, with a focus on patient selection criteria, surgical techniques, perioperative considerations on timing of interventions, and long-term results. We believe that septation of the double-inlet ventricle should be reconsidered in patients with suitable anatomy in light of the known complications of Fontan palliation.


Assuntos
Técnica de Fontan , Coração Univentricular , Septo Interventricular , Humanos , Ventrículos do Coração/cirurgia , Baías , Septo Interventricular/cirurgia
2.
J Cardiothorac Surg ; 19(1): 53, 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38311759

RESUMO

BACKGROUND: Sinus of Valsalva aneurysm (SVA) is an extremely rare condition, and its rupture causes acute symptoms such as chest pain and dyspnea. Ruptured SVA is frequently associated with other congenital defects. CASE PRESENTATION: A 37-year-old male presented with SVA originating from the left coronary sinus that ruptured into the interventricular septum. SVA was diagnosed by echocardiography, cardiac computed tomography and magnetic resonance imaging, and confirmed during the operation. CONCLUSIONS: SVA is a rare cardiac abnormality which can lead to severe clinical symptoms upon rupture. Immediate surgery is necessary to repair the ruptured SVA.


Assuntos
Aneurisma Aórtico , Doenças da Aorta , Dissecção Aórtica , Ruptura Aórtica , Seio Coronário , Seio Aórtico , Septo Interventricular , Masculino , Humanos , Adulto , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia , Seio Aórtico/patologia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Doenças da Aorta/complicações , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/diagnóstico por imagem
3.
J Cardiothorac Surg ; 19(1): 48, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310275

RESUMO

BACKGROUND: Penetrating cardiac injuries are rare but often fatal, with 16-55% mortality. We report a patient who suffered a non-fatal occupational cardiac injury. CASE PRESENTATION: A 47-year-old man was operating an ironworker machine. A thin 3-cm metal fragment catapulted from the machine piercing the chest wall and the right ventricular outflow tract (RVOT), burrowing into the interventricular septum (IVS). The patient remained hemodynamically stable and walked to the nearest hospital. ECG-gated computed tomography revealed the exact location of the fragment within the IVS, allowing for detailed preoperative planning. The fragment was removed through a sternotomy and an incision through the RVOT. The postoperative course was uneventful. CONCLUSIONS: This case underscores the value of detailed preoperative imaging and the wide spectrum of clinical scenarios of penetrating cardiac injuries.


Assuntos
Corpos Estranhos , Traumatismos Cardíacos , Septo Interventricular , Ferimentos Penetrantes , Masculino , Humanos , Pessoa de Meia-Idade , Septo Interventricular/cirurgia , Ferimentos Penetrantes/diagnóstico , Ferimentos Penetrantes/cirurgia , Ventrículos do Coração/cirurgia , Ventrículos do Coração/lesões , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
4.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37831900

RESUMO

OBJECTIVES: This study aimed to assess the effectiveness of three-dimensional printing (3DP) in patients with complex hypertrophic cardiomyopathy requiring combined transaortic and transapical septal myectomy. METHODS: We created 3DP models for 7 patients undergoing this surgery approach between June and October 2022 using silicone-like resin and conducted mock operations. The models were compared with echocardiography to identify abnormal muscle bundles and heart structures. These patients were then compared with a 1:2 matched group without 3DP, considering age, sex and additional operations. RESULTS: The models mostly presenting with midventricular obstruction showed high consistency with original computed tomography data (r = 0.978, P < 0.001). 3DP identified more abnormal muscle bundles than echocardiography, primarily between the interventricular septum and apex. Excised specimens in mock operations mirrored those in actual myectomies. While cardiopulmonary bypass time was not significantly different, a near-20-min decrease was observed in the 3DP group (135.5 ± 31.1 vs 154.4 ± 36.6 min, P = 0.054). CONCLUSIONS: While no significant differences in surgical outcomes were observed, 3DP appeared to enhance the visualization and understanding of spatial structures (average Likert scale score 4.0), potentially contributing to surgical proficiency (overall rating score 3.9). The use of 3DP may offer additional value in the preparation and execution of operations for complex hypertrophic cardiomyopathy cases.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiomiopatia Hipertrófica , Septo Interventricular , Humanos , Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Septo Interventricular/cirurgia , Ponte de Artéria Coronária , Impressão Tridimensional , Resultado do Tratamento
5.
Cardiol Young ; 34(1): 120-125, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37231590

RESUMO

Pulmonary atresia with an intact ventricular septum is characterised by heterogeneity in right ventricle morphology and coronary anatomy. In some cases, the presence of ventriculocoronary connections may promote coronary artery stenosis or interruption, and aortic diastolic pressure may not be sufficient to drive coronary blood flow. This requires a correct evaluation (currently done by angiography) which depends on whether the patient can be offered decompression of the right ventricle. To date, there is no objective method to do so, so we designed a percutaneous, transitory technique with the purpose of occluding the transtricuspid anterograde flow. The manoeuverer was performed in a 25-day-old female with pulmonary atresia with intact ventricular septum, right ventricle at suprasystemic level, and selective coronarography was not conclusive, the anterior descendant with stenosis in its middle third and from this point, thinner with to-fro flow. Occlusion was performed with a balloon catheter. We re-evaluated the coronary flow and the normalised anterior descendant flow. We hope that with this new method, we can give a more accurate diagnosis and determine the cases in which the coronary circulation is truly not right ventricle dependent to offer a greater number of patients biventricular or 1.5 ventricular repairs and thereby improve their quality of life and survival, the ones that turn out to be right ventricular dependant; offer them an early reference for cardiac transplant or in case it is not available to consider univentricular palliation knowing that this probably would not reduce the risk of ischaemia and/or death over time.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Septo Interventricular , Humanos , Feminino , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Ventrículos do Coração , Qualidade de Vida , Resultado do Tratamento , Circulação Coronária
9.
J Am Heart Assoc ; 12(21): e031090, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37929755

RESUMO

Background Patients with pulmonary atresia or critical pulmonary stenosis with intact ventricular septum (PA/IVS) and biventricular circulation may require pulmonary valve replacement (PVR). Right ventricular (RV) remodeling after PVR is well described in tetralogy of Fallot (TOF); we sought to investigate RV changes in PA/IVS using cardiac magnetic resonance imaging. Methods and Results A retrospective cohort of patients with PA/IVS who underwent PVR at Boston Children's Hospital from 1995 to 2021 with cardiac magnetic resonance imaging before and after PVR was matched 1:3 with patients with TOF by age at PVR. Median regression modeling was performed with post-PVR indexed RV end-diastolic volume as the primary outcome. A total of 20 patients with PA/IVS (cases) were matched with 60 patients with TOF (controls), with median age at PVR of 14 years. Pre-PVR indexed RV end-diastolic volume was similar between groups; cases had higher RV ejection fraction (51.4% versus 48.6%; P=0.03). Pre-PVR RV free wall and left ventricular (LV) longitudinal strain were similar, although LV midcavity circumferential strain was decreased in cases (-15.6 versus -17.1; P=0.001). At a median of 2 years after PVR, indexed RV end-diastolic volume was similarly reduced; cases continued to have higher RV ejection fraction (52.3% versus 46.9%; P=0.007) with less reduction in RV mass (Δ4.5 versus 9.6 g/m2; P=0.004). Post-PVR, RV and LV longitudinal strain remained unchanged, and LV circumferential strain was similar, although lower in cases. Conclusions Compared with patients with TOF, patients with PA/IVS demonstrate similar RV remodeling after PVR, with lower reduction in RV mass and comparatively higher RV ejection fraction. Although no differences were detected in peak systolic RV or LV strain values, further investigation of diastolic parameters is needed.


Assuntos
Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Atresia Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Septo Interventricular , Criança , Humanos , Adolescente , Valva Pulmonar/cirurgia , Septo Interventricular/cirurgia , Estudos Retrospectivos , Constrição Patológica , Cardiopatias Congênitas/cirurgia , Tetralogia de Fallot/cirurgia , Função Ventricular Direita , Remodelação Ventricular , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
10.
BMC Cardiovasc Disord ; 23(1): 346, 2023 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438743

RESUMO

BACKGROUND: Rare as membranous ventricular septal aneurysms (MVSA) is, the possibility that occurs after ventricular septum defect (VSD) repair surgery is even more uncommon. PRESENTATION: A girl developed a MVSA 3 years after the VSD repair surgery at the age of 1 and increasing growth was noted during the follow-up. Aneurysm plication was carried done when she was 11 years old because it was observed to have a close relationship to the right coronary and obstructed the right ventricular outflow tract. Postoperative echocardiography follow-up revealed no abnormalities. CONCLUSION: Though the prognosis of most patients with VSD repaired surgery was good, there remains varieties type of complications despite surgical advances. Accurate and rapid diagnosis of acute and delayed complications is essential to improve prognosis. In this case, the aneurysm was diagnosed by multiple imaging modalities and the girl underwent successful surgery again which provides direction for awareness and knowledge of delayed complications of VSD repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Aneurisma Cardíaco , Comunicação Interventricular , Septo Interventricular , Feminino , Humanos , Criança , Seguimentos , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/cirurgia , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia
12.
J Cardiothorac Surg ; 18(1): 173, 2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37149618

RESUMO

BACKGROUND: Human hydatid disease occurs after infection with Echinococcus granulosus, mainly involves liver and lung, while hydatid involves heart is infrequent. A great majority of hydatid diseases could be asymptomatic, and incidentally found through examination. Here, we reported a woman who suffered an isolated cardiac hydatid cyst located at the interventricular septum. CASE PRESENTATION: A 48-year-old woman presented intermittent chest pain was admitted to the hospital. Imaging examination revealed a cyst located at the interventricular septum near the right ventricular apex. Considering medical history, radiological findings and serological results, cardiac hydatid disease was suspected. The cyst was successfully removed, while pathological biopsy confirmed the diagnosis of infection of Echinococcus granulosus. Postoperative course was uneventful, the patient was discharged from hospital without complications. CONCLUSION: For symptomatic cardiac hydatid cyst, surgical resection is necessary to avoid progression of disease. During surgical procedure, appropriate methods to reduce the potential risk of hydatid cyst metastasis are essential. Besides surgery, combined with regular drug therapy is an effective strategy to prevent reappearance.


Assuntos
Cistos , Equinococose , Echinococcus granulosus , Cardiopatias , Septo Interventricular , Feminino , Animais , Humanos , Pessoa de Meia-Idade , Equinococose/complicações , Equinococose/diagnóstico , Equinococose/cirurgia , Septo Interventricular/cirurgia , Cardiopatias/cirurgia , Dor no Peito/etiologia , Cistos/complicações
14.
World J Pediatr Congenit Heart Surg ; 14(4): 500-502, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37006129

RESUMO

Early and long-term outcomes in patients with pulmonary atresia-intact ventricular septum undergoing staged univentricular palliations have been known to be adversely affected by the presence of right ventricle-dependent coronary circulation. We describe a surgical technique to circumvent the coronary insufficiency caused by acute decompression of the right heart.


Assuntos
Atresia Pulmonar , Septo Interventricular , Humanos , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Ponte Cardiopulmonar , Atresia Pulmonar/cirurgia , Septo Interventricular/cirurgia , Perfusão , Circulação Coronária , Descompressão
16.
Zhonghua Wai Ke Za Zhi ; 61(3): 196-200, 2023 Mar 01.
Artigo em Chinês | MEDLINE | ID: mdl-36650964

RESUMO

Septal reduction therapies, which include septal myectomy and alcohol septal ablation and so on, are the current treatment strategies for patients with obstructive hypertrophic cardiomyopathy and drug-refractory symptoms. With the deepening of theoretical understanding and the rapid development of interventional therapies, some researchers have tried to perform transcatheter mitral valve edge-to-edge repair to treat high-risk patients with hypertrophic cardiomyopathy, including obstructive and non-obstructive. The reported results are relatively satisfactory, but many urgent problems need to be solved, such as the lack of data on animal experiments and large cohort studies, and the unknown medium- and long-term outcomes. However, transcatheter mitral valve edge-to-edge repair brings new ideas for the diagnosis and treatment of patients with hypertrophic cardiomyopathy. On one hand, it can be used as a monotherapy, on the other hand, it can be combined with novel molecular targeted drug therapy or emerging minimally invasive surgical procedures targeting hypertrophic ventricular septum, which deserves our further attention and exploratory research.


Assuntos
Cardiomiopatia Hipertrófica , Septo Interventricular , Humanos , Resultado do Tratamento , Cardiomiopatia Hipertrófica/cirurgia , Valva Mitral/cirurgia , Septo Interventricular/cirurgia , Hipertrofia
17.
Zhonghua Wai Ke Za Zhi ; 61(3): 209-213, 2023 Mar 01.
Artigo em Chinês | MEDLINE | ID: mdl-36650966

RESUMO

Objective: To examine the short-term curative effect with minimally invasive right infra-axillary thoracotomy for transaortic modified Morrow procedure. Methods: The clinical data of 60 patients who underwent video-assisted thoracoscopic transaortic modified Morrow procedure from August 2021 to August 2022 at Department of Cardiovascular Surgery, Zhejiang Provincial People's Hospital were retrospectively analyzed. There were 31 males and 29 females, with the age (M (IQR)) of 54.0(22.3) years (range: 15 to 71 years). The echocardiography confirmed the diagnosis of moderate mitral regurgitation in 30 patients, and severe mitral regurgitation in 13 patients. Systolic anterior motion (SAM) was present preoperatively in 54 patients. All 60 patients underwent transaortic modified Morrow procedure through a right infra-axillary thoracotomy using femorofemoral cardiopulmonary bypass. Surgical procedures mainly included transverse aortic incision, exposure of left ventricular outflow tract (LVOT), septal myectomy, and correction of the abnormal mitral valve and subvalvular structures. Results: All 60 patients underwent the programmatic procedures successfully without conversion to full sternotomy. The cardiopulmonary bypass time was (142.0±32.1) minutes (range: 89 to 240 minutes), while the cross-clamp time was (95.0±23.5) minutes (range: 50 to 162 minutes). The patients had a postoperative peak LVOT gradient of 7.0 (5.0) mmHg (range: 0 to 38 mmHg) (1 mmHg=0.133 kPa). A total of 57 patients were extubated on the operating table. The drainage volume in the first 24 h was (175.9±57.0) ml (range: 60 to 327 ml). The length of intensive care unit stay was 21.0 (5.8)h (range: 8 to 120 h) and postoperative hospital stay was 8 (5) days (range: 5 to 19 days). The postoperative septal thickness was 11 (2) mm (range: 8 to 14 mm). All patients had no iatrogenic ventricular septal perforation or postoperative residual SAM. The patients were followed up for 4 (9) months (range: 1 to 15 months), and none of them needed cardiac surgery again due to valve dysfunction or increased peak LVOT gradient during follow-up. Conclusion: Using a video-assisted thoracoscopic transaortic modified Morrow procedure through a right infra-axillary minithoracotomy can provide good visualization of the LVOT and hypertrophic ventricular septum, ensure optimal exposure of the mitral valve in the presence of complex mitral subvalvular structures, so that allows satisfactory short-term surgical results.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Septo Interventricular , Masculino , Feminino , Humanos , Insuficiência da Valva Mitral/cirurgia , Toracotomia , Estudos Retrospectivos , Cardiomiopatia Hipertrófica/cirurgia , Septo Interventricular/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
19.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36269173

RESUMO

OBJECTIVES: Transaortic myectomy is a common procedure for patients with hypertrophic obstructive cardiomyopathy. Thoracoscopic trans-mitral myectomy has been described in a few small-sample studies and has been recommended as preferable. We herein report our clinical outcomes using the thoracoscopic trans-mitral approach with 76 patients. METHODS: This is a retrospective single-centre analysis of the safety and efficacy of thoracoscopic trans-mitral myectomy by comparing the clinical outcomes with that of transaortic myectomy. RESULTS: Between April 2019 and October 2021, 132 patients underwent either a transaortic (n = 56) or a thoracoscopic trans-mitral myectomy (n = 76). Compared with those in the transaortic group, patients in the trans-mitral group were more likely to be weaned off the ventilator within 24 h after surgery (80.3% vs 60.7%, P < 0.05) and to require a shorter duration of ventilation [29.01 (43.91) vs 51.12 (94.96) h, P = 0.08] and lower transfusion rate (26.3% vs 48.2%, P < 0.05). The in-hospital mortality rate of the transaortic and trans-mitral groups was 3.6% (n = 2) and 1.3% (n = 1), respectively. No significant inter-group differences were observed regarding in-hospital mortality, the incidence of low cardiac output syndrome or permanent pacemaker implantations. In the trans-mitral group, the thickness of the interventricular septum was significantly reduced postoperatively, with resultant relief of the left ventricular outflow tract obstruction [89.37 (27.5) vs 10.51 (0.65) mmHg, P < 0.01]. Transaortic myectomy also resulted in a significant reduction in left ventricular outflow tract gradient [90.41 (33.31) vs 11.35 (9.43) mmHg, P < 0.01]. And the incidence of residual systolic anterior motion of the trans-mitral group and the transaortic group was 2.67% and 1.9%, respectively. CONCLUSIONS: The thoracoscopic trans-mitral approach provides excellent exposure to the septum and anomalies of the mitral valve and papillary muscle. It relieves obstruction effectively, without increasing the incidence of major complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Septo Interventricular , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Septo Interventricular/cirurgia , Cardiomiopatia Hipertrófica/complicações , Insuficiência da Valva Mitral/cirurgia
20.
Ann Thorac Surg ; 115(6): 1470-1477, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36070807

RESUMO

BACKGROUND: Multicenter contemporary data describing short-term outcomes after initial interventions of neonates with pulmonary atresia with intact ventricular septum (PA-IVS) are limited. This multicenter study describes characteristics and outcomes of PA-IVS neonates after their initial catheter or surgical intervention and identifies factors associated with major adverse cardiac events (MACE). METHODS: Neonates with PA-IVS who underwent surgical or catheter intervention between 2009 and 2019 in 19 centers were reviewed. Risk factors for MACE, defined as cardiopulmonary resuscitation, mechanical circulatory support, stroke, or in-hospital mortality, were analyzed using multivariable logistic regression models. RESULTS: We reviewed 279 neonates: 79 (28%) underwent right ventricular decompression, 151 (54%) underwent systemic-to-pulmonary shunt or ductal stent placement only, 36 (13%) underwent right ventricular decompression with shunt or ductal stent placement, and 11 (4%) underwent transplantation. MACE occurred in 57 patients (20%): 26 (9%) received mechanical circulatory support, 37 (13%) received cardiopulmonary resuscitation, stroke occurred in 16 (6%), and 23 (8%) died. The presence of 2 major coronary artery stenoses (adjusted odds ratio, 4.99; 95% CI, 1.16-21.39) and lower weight at first intervention (adjusted odds ratio, 1.52; 95% CI, 1.01-2.27) were significantly associated with MACE. Coronary ischemia was the most frequent presumed mechanism of death (n = 10). CONCLUSIONS: In a multicenter cohort, 1 in 5 neonates with PA-IVS experienced MACE after their initial intervention. Patients with 2 major coronary artery stenoses or lower weight at the time of the initial procedure were most likely to experience MACE and warrant vigilance during preintervention planning and postintervention management.


Assuntos
Estenose Coronária , Cardiopatias Congênitas , Atresia Pulmonar , Acidente Vascular Cerebral , Septo Interventricular , Recém-Nascido , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Septo Interventricular/cirurgia , Estudos Multicêntricos como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...